Setting Specification Limits for Dart Impact (M50): A Step-by-Step Approach

Setting Specification Limits for Dart Impact (M50): A Step-by-Step Approach

A structured method to turn M50 results into meaningful dart impact specifications that link directly to field performance.

Setting Specification Limits for Dart Impact (M50): A Step-by-Step Approach

One of the key challenges in implementing dart impact testing is deciding what acceptance criteria should be. The impact failure mass M50 is a powerful metric, but turning it into a meaningful specification requires a structured approach. Without clear limits, impact testing becomes a diagnostic tool only, rather than a proactive QC instrument.

The first step is data collection. Before defining any limits, you should gather M50 data from a representative set of products. This should include films that are known to perform well in the field and, if possible, films associated with historical complaints or failures. For each film type, run a sufficient number of tests under defined conditions (such as temperature, humidity, and Method A or B) and document the results with sample IDs and production information.

Next, analyze the distribution of M50 values for the “good” and “problematic” groups. In many cases, you will find that films with reliable performance have M50 values clustered above a certain level, while those associated with failures cluster below that level. The overlap region is important: if there is significant overlap, it may indicate that other factors, such as seal integrity or product sharpness, also play a major role. Nonetheless, the analysis typically reveals a threshold below which the risk of failure increases sharply.

Once you have a preliminary threshold, you can draft a specification. For example, you might state that “for Product X, the dart impact M50 value shall not be less than 350 g under Method A at 23 °C” or “for frozen packaging applications, the M50 shall not be less than 250 g after conditioning at -20 °C for 24 hours.” The specification should reference the test standard, method (A or B), conditioning conditions, and the minimum acceptable M50. This clarity prevents confusion when data are exchanged between suppliers, internal plants, and customers.

After drafting the specification, a validation phase is recommended. Over several months, apply the preliminary limits to routine production, while continuing to monitor complaint rates and field feedback. If you find that batches above the limit still produce unexpected failures, the limit may need to be raised or combined with additional criteria (such as seal-strength requirements). If no issues occur and the film is clearly stronger than necessary, you may consider carefully adjusting the limit or exploring responsible downgauging.

Finally, documentation and communication are crucial. The method used to define the specification, the underlying data, and any assumptions should be recorded. Specifications should be included in drawings, quality agreements, and internal SOPs. When new grades, structures, or suppliers are introduced, the same process should be applied or the existing limits should be revalidated. This step-by-step approach ensures that M50 is not just a number on a report but a well-founded metric tied directly to real-world performance.

About Author
Amy Gu
Amy Gu
Amy Gu is a Senior Technical Specialist and Product Manager at KHT, with over 8 years of expertise in material mechanics and flexible packaging testing. She holds a Master's degree in Material Science and specializes in impact resistance analysis for the pharmaceutical, food, and logistics industries. Amy has successfully led the deployment of KHT's MLB Series Falling Dart Impact Testers globally, helping clients ensure strict compliance with ASTM D1709, ISO 7765, and GB/T 9639 standards. Her deep understanding of the 'Staircase Method' and pneumatic clamping technologies enables her to provide expert guidance on film durability, preventing costly packaging failures during transport. Amy is committed to delivering high-precision impact testing solutions that meet the rigorous safety demands of modern quality control laboratories.

Ready to Prevent Packaging Failure?

Act Now

Get the factory-direct precision you need to comply with ASTM D1709, ISO 7765-1, and GB/T 9639.1. Contact KHT for a customized quote today.

View our privacy policy.

© 2025 KHT MLB-01 Impact Tester | All rights reserved.